Re: Inductive Z-Sensor Z-axis don't move when sensor is active.

You're right, now it works (:P) Thanks alot (tu) I would never have guessed since the sensor is indeed as a hardware endstop.

View Article


Re: Extruder motor don't move

Two comments. First, you have to have the nozzle up to temperature before Marlin will attempt to move the extruder motor. It will typically issue a 'Cold extrusion attempted.' message if the nozzle is...

View Article


Re: Need to recover firmware settings.

It won't take that long to reverse engineer the settings. Just compile and load the latest RCBugFix code. And see if you can see each end stop and move the axis in the correct direction. You can...

View Article

Re: MARLIN 31/07/16 - Z_RAISE_BEFORE_HOMING missing

It is helpful to know the history. The Z_RAISE options got added one at a time to fix various issues. We ended up with way too many Z_RAISE options. It was complicating the code because different...

View Article

Re: Mesh bed leveling is not active

Actually... That will work, but I only left the M420 in place to be backward compatible. Doing a G29 A will activate the UBL System. Doing a G29 A S1 will save the current mesh state and mesh in...

View Article


Re: Nozzle Cleaning [1.1.0 RC7]

Quotebrucehvn Can it help with cleaning blobs off the nozzle before doing mesh bed leveling calibrations? That's my biggest pain is making sure the nozzle is clean so as not to add fake distance...

View Article

Re: Mesh bed leveling is not active

QuoteRoxy Actually... That will work, but I only left the M420 in place to be backward compatible. Doing a G29 A will activate the UBL System. Doing a G29 A S1 will save the current mesh state and...

View Article

Re: Nozzle Cleaning [1.1.0 RC7]

QuoteRoxy It is especially useful for dual extruder machines when you switch from one nozzle to the other. But some people are using it on single extruder machines to clean up the nozzle prior to a...

View Article


Re: Mesh bed leveling is not active

Well, those commands are in RC-7. But I was referring to the devel_ubl branch instead of RCBugFix. The foundation of the Unified Bed Leveling is a High Resolution Mesh. But in the UBL system, the Mesh...

View Article


Re: Nozzle Cleaning [1.1.0 RC7]

I think a Scotch Bright pad would work well. I have not used the Wipe Feature. But my assumption is it does not extrude. The whole purpose is to clean the nozzle.

View Article

Re: Extruder motor don't move

Hello Roxy, yes the nozzle has 185°C as I test the extruder. I also have test it with cold nozzle but then the stepper motor became no power (cold extrusion protection). The potentiometer have I...

View Article

Final Heat bed degree not reached

Hi, I had tried to search if this happened to anyone before but could not find anything so far. Whenever I am starting a print with heated bed target temp to be above 100 the last degree is not...

View Article

Re: Need to recover firmware settings.

Thanks guys, I've followed all the advice and I am pretty close to having it back. I will also store a copy of the firmware in the cloud so this does not happen again. Jerry

View Article


Re: Final Heat bed degree not reached

I guess by posting I have tapped into reprap hive consciousness as day later I had 2 ideas: 1 - Switch to bang- bang mode for heated bed- Temp achieved, overshoots a little so further stability...

View Article

Re: Final Heat bed degree not reached

Maybe the display only cuts off the last digit and the real temp is 109.9 where 110 was the goal? Did you copy&paste the PID values from autotune into firmware and safed them into eeprom too?

View Article


Re: Final Heat bed degree not reached

Thanks for your reply. Its not the case for the display as I also watched feedback via pronterface. Only always flashed firmware with PID values and never Eprom. will try that.

View Article

Re: how to change board

Dear Sir, I am using sanguino with 1284P Quad with 12864 GLCD. I wanted to interface it with Proteus Software. Please help me with it sir. ShriHari shri.7175@gmail.com

View Article


Re: Marlin firmware rev sanguinololu 1.3a

Dear Sir, I am using sanguino with 1284P Quad with 12864 GLCD. I wanted to interface it with Proteus Software. Please help me with it sir. ShriHari shri.7175@gmail.com

View Article

Re: Marlin firmware rev sanguinololu 1.3a

Dear Sir, I am using sanguino with 1284P Quad with 12864 GLCD. I wanted to interface it with Proteus ISIS Electronic Simulator Software. Please help me with it sir. Reply ShriHari shri.7175@gmail.com

View Article

Re: Marlin firmware rev sanguinololu 1.3a

Dear Sir, I am using sanguino with 1284P Quad with 12864 GLCD. I wanted to interface it with Proteus ISIS Electronic Simulator Software. Please help me with it sir. Reply sir ShriHari shri.7175@gmail.com