Re: Thermistor selection Marlin 1.1.8

$
0
0
Can someone plz take a look at this and tell me if I did this right?

I attached an Excel sheet of the info below as formatting doesn't look right on a cut paste from Excel....
The table creator I found was setup to make the table for every 5 deg but the data I had was every 10 deg so I adapted.
Will this be a problem?
Now how to use this......

Do I just cut paste over an existing thermistor table and use the # of that table in my config?

Thanx in advance :)


Deg C - RT RT/100 Marlin Table


0 354.6 3.546 { 283 , 300 },
10 208.8 2.088 { 326 , 290 },
20 126.9 1.269 { 376 , 280 },
30 79.33 0.7933 { 436 , 270 },
40 50.9 0.509 { 509 , 260 },
50 33.45 0.3345 { 596 , 250 },
60 22.48 0.2248 { 701 , 240 },
70 15.43 0.1543 { 830 , 230 },
80 10.8 0.108 { 987 , 220 },
90 7.69 0.0769 { 1180 , 210 },
100 5.569 0.05569 { 1416 , 200 },
110 4.097 0.04097 { 1708 , 190 },
120 3.058 0.03058 { 2067 , 180 },
130 2.313 0.02313 { 2507 , 170 },
140 1.77 0.0177 { 3045 , 160 },
150 1.371 0.01371 { 3696 , 150 },
160 1.074 0.01074 { 4478 , 140 },
170 0.8501 0.008501 { 5398 , 130 },
180 0.6793 0.006793 { 6452 , 120 },
190 0.5476 0.005476 { 7623 , 110 },
200 0.4452 0.004452 { 8877 , 100 },
210 0.365 0.00365 { 10159 , 90 },
220 0.3016 0.003016 { 11405 , 80 },
230 0.251 0.00251 { 12546 , 70 },
240 0.2104 0.002104 { 13538 , 60 },
250 0.1775 0.001775 { 14351 , 50 },
260 0.1507 0.001507 { 14984 , 40 },
270 0.1287 0.001287 { 15452 , 30 },
280 0.1105 0.001105 { 15783 , 20 },
290 0.09539 0.000954 { 16008 , 10 },
300 0.08278 0.000828 { 16154 , 0 },